Summary
When mounting a backup image by using the currently available AIP2018 Update 5 or later and HyperBoot, iSCSI Server is used for internal processing.
However, when upgrading to the latest version of ActiveVisor or ImageCenter deletes iSCSI Server. Therefore, when AIP 2018 Update 5 or later or HyperBoot is installed, iSCSI Server is uninstalled from the PC. As a result, AIP 2018 Update 5 or later and HyperBoot does not behave properly.
Workaround
Please run SetupISCSI.exe located in the default install folder and install iSCSI Server again.
– C:Program Files (x86)ActiphyActiveImage Protector
– C:Program Files (x86)NetJapanActiveImage Protector
In case of HyperBoot, reinstallation of HyperBoot installs iSCSI Server again.
Target Product
– ActiveImage Protector 2018 Update 5 or later
– HyperBoot
Comments
0 comments